Local rules in San Francisco (County)
Which rules should you check?
Statewide laws
SB 326 — condominium associations
San Francisco County rules
The county code covers building and filing requirements in unincorporated areas. For a property inside city limits, check the city’s rules and confirm which county requirements apply at the address.
Residential balcony and exterior element research
These findings concern residential balconies, decks, exterior stairs, walkways and related fire escapes. Check the property scope and trigger: some duties apply during construction, after a notice, or when an inspection report is filed.
Inspection and reporting provisions
Structural examination of fire escapes
Check structural adequacy and safety, including the ability to carry dead load plus the live load specified in the original design. Maintain the report on site for immediate production on request.
Verified mixed credentials
- Residential scope only: Covered fire escape stairs and balconies.
- Every five years or more frequently when requested by the fire code official.
- Registered design professional or other person acceptable to fire code official for the examination. Registered design professional must determine structural adequacy if original structural design calculations are unavailable.
- Use the local design-load rule. The separate §604 affidavit does not displace the Fire Code schedule.
- Current 2025-edition SF Fire Code online text §§1104.16.5 and 1104.16.5.1.
- San Francisco Fire Code §§1104.16.5 and 1104.16.5.1
- Supporting source
- 2025 San Francisco Fire Code §§ 1104.16.5 and 1104.16.5.1
- Supporting source
Supporting research details
Structural examination of fire escape stairs and balconies · Authority scope and qualifications vary
- Keep the report on site. Separate legal basis from Housing Code § 604, with potential overlap for a given building.
- Residential scope only: Fire escape stairways and balconies subject to the local fire code
- Every 5 years or sooner when the fire code official requests it
- Registered design professional or someone acceptable to the fire code official. A registered design professional must determine adequacy when the original calculations are unavailable.
- 80–81
Weather-exposed structural elements and exits
Have a qualifying professional check all covered weather-exposed elements for safe working condition, rot, fungus, deterioration, decay and improper alterations. File the signed DBI affidavit.
Verified mixed credentials
- Residential scope only: covered weather-exposed wood and metal decks, balconies, landings, exit corridors, stairs, guards, handrails and fire escapes at apartment buildings, including covered residential condominiums with three or more dwellings. Confirm the definitions in Housing Code §401.
- Every six years. For properties subject to California Health and Safety Code (HSC) §17973, one advance or deferral may align deadlines, with no more than seven years between local filings.
- CSLB A, B or C-5 contractor with five years holding the qualifying classification and five years constructing multistory wood-frame buildings, recognized certified building inspector/official, or licensed architect/civil/structural engineer.
- Older DBI notice lists five years and a pest-control route removed by 92-26. Alignment is limited to §17973. State duties and SF Fire Code §1104.16.5.1 must be evaluated independently.
- Current online code; signed Ordinance 92-26 PDF pp. 2–3
- San Francisco Housing Code §§401 and 604(a); Ordinance 92-26, effective June 15, 2026
- Supporting source
- Signed Ordinance 92-26, pp. 2–3
Supporting research details
Weather-exposed structural elements and exits · Historical source
- Owner files the signed affidavit with Housing Inspection Services. Residential condominium coverage is subject to §401. The former five-year guidance and former pest-control route are superseded by Ordinance 92-26. Check state and fire-code duties separately.
- Residential scope only: Weather-exposed decks, balconies, landings, corridors, stairways, rails and fire escapes at covered apartments
- Every six years; one-time alignment with HSC §17973 may allow up to seven years between affidavits.
- CSLB A, B or C-5 contractor with five years holding the qualifying classification and five years constructing multistory wood-frame buildings, recognized certified building inspector/official, or licensed architect/civil/structural engineer.
- Ordinance 92-26, pp. 2–3
Special district rules
Fire and other special districts serve defined areas. Their boundaries can overlap or cross city limits. Use the links below to check which offices and rules cover the property address.
Cities and Unincorporated Communities within San Francisco County
Incorporated cities
Last researched date: November 2, 2026
An asterisk marks cities and counties with additional local rules or code information. Check the detail page for scope and any unresolved findings.