Local rules in San Francisco (City)
Which rules should you check?
Statewide Laws
SB 326 — condominium associations
San Francisco County rules
The county code covers building and filing requirements in unincorporated areas. For a property inside city limits, check the city’s rules and confirm which county requirements apply at the address.
Residential balcony and exterior element research
These findings concern residential balconies, decks, exterior stairs, walkways and related fire escapes. Check the property scope and trigger: some duties apply during construction, after a notice, or when an inspection report is filed.
Inspection and reporting provisions
Structural examination of fire escapes
Check structural adequacy and safety, including the ability to carry dead load plus the live load specified in the original design. Maintain the report on site for immediate production on request.
Verified mixed credentials
- Residential scope only: Covered fire escape stairs and balconies.
- Every five years or more frequently when requested by the fire code official.
- Registered design professional or other person acceptable to fire code official for the examination. Registered design professional must determine structural adequacy if original structural design calculations are unavailable.
- Use the local design-load rule. The separate §604 affidavit does not displace the Fire Code schedule.
- Current 2025-edition SF Fire Code online text §§1104.16.5 and 1104.16.5.1.
- San Francisco Fire Code §§1104.16.5 and 1104.16.5.1
- Supporting source
- 2025 San Francisco Fire Code §§ 1104.16.5 and 1104.16.5.1
- Supporting source
Supporting research details
Structural examination of fire escape stairs and balconies · Authority scope and qualifications vary
- Keep the report on site. Separate legal basis from Housing Code § 604, with potential overlap for a given building.
- Residential scope only: Fire escape stairways and balconies subject to the local fire code
- Every 5 years or sooner when the fire code official requests it
- Registered design professional or someone acceptable to the fire code official. A registered design professional must determine adequacy when the original calculations are unavailable.
- 80–81
Weather-exposed structural elements and exits
Have a qualifying professional check all covered weather-exposed elements for safe working condition, rot, fungus, deterioration, decay and improper alterations. File the signed DBI affidavit.
Verified mixed credentials
- Residential scope only: covered weather-exposed wood and metal decks, balconies, landings, exit corridors, stairs, guards, handrails and fire escapes at apartment buildings, including covered residential condominiums with three or more dwellings. Confirm the definitions in Housing Code §401.
- Every six years. For properties subject to California Health and Safety Code (HSC) §17973, one advance or deferral may align deadlines, with no more than seven years between local filings.
- CSLB A, B or C-5 contractor with five years holding the qualifying classification and five years constructing multistory wood-frame buildings, recognized certified building inspector/official, or licensed architect/civil/structural engineer.
- Older DBI notice lists five years and a pest-control route removed by 92-26. Alignment is limited to §17973. State duties and SF Fire Code §1104.16.5.1 must be evaluated independently.
- Current online code; signed Ordinance 92-26 PDF pp. 2–3
- San Francisco Housing Code §§401 and 604(a); Ordinance 92-26, effective June 15, 2026
- Supporting source
- Signed Ordinance 92-26, pp. 2–3
Supporting research details
Weather-exposed structural elements and exits · Historical source
- Owner files the signed affidavit with Housing Inspection Services. Residential condominium coverage is subject to §401. The former five-year guidance and former pest-control route are superseded by Ordinance 92-26. Check state and fire-code duties separately.
- Residential scope only: Weather-exposed decks, balconies, landings, corridors, stairways, rails and fire escapes at covered apartments
- Every six years; one-time alignment with HSC §17973 may allow up to seven years between affidavits.
- CSLB A, B or C-5 contractor with five years holding the qualifying classification and five years constructing multistory wood-frame buildings, recognized certified building inspector/official, or licensed architect/civil/structural engineer.
- Ordinance 92-26, pp. 2–3
Special district rules
Fire and other special districts serve defined areas. Their boundaries can overlap or cross city limits. Use the links below to check which offices and rules cover the property address.
San Francisco City Rules
Local E3 material coverage
Housing Code § 604(a) covers weather-exposed wood and metal decks, balconies, landings, exit corridors, stairways, guardrails, handrails and fire escapes at apartment buildings and hotels. Steel structures can qualify under the metal scope. Owners file the signed inspection affidavit every six years. Properties subject to SB 721 can align the filing once, with at most seven years between affidavits.
San Francisco Housing Code § 604(a)Balcony and Exterior Elevated Elements inspections
Weather-exposed structural elements and exits
For covered weather-exposed wood or metal exterior elements at residential apartment buildings, including qualifying condominiums, arrange a qualified inspection and file the signed affidavit with Housing Inspection Services every six years. Properties subject to California Health and Safety Code (HSC) §17973 may align the filing once, with at most seven years between affidavits.
- Authority: San Francisco
- Applies to: Residential scope only: covered weather-exposed wood or metal exterior elements at apartment buildings, including qualifying condominiums under Housing Code §401.
- Inspection cycle: Six years. One-time alignment with §17973 may allow up to seven years between affidavits.
- Who can inspect: A licensed architect or civil or structural engineer, a recognized certified building inspector or official, or an A, B or C-5 contractor with five years holding the required license and five years building multistory wood-frame buildings. A person hired for this inspection must not be employed by the City and County while performing it.
- Effective date: 2026-06-15
- Scope and exceptions: See §604(a) for contractor experience and the optional deadline alignment. Fire-escape examination under the Fire Code is a separate duty.
Related residential exterior element inspections
Check residential fire-escape and related exterior element inspection duties separately. Scope and timing can depend on the property, element or inspection trigger.
Structural examination of fire escapes
Have a registered design professional or another person the fire code official accepts examine covered fire-escape stairs and balconies for structural safety at least every five years. The official may require more frequent examination. Keep the report on site and make it immediately available if the official requests it.
- Authority: San Francisco
- Applies to: Covered fire escape stairs and balconies.
- Inspection cycle: Every five years or more often if required.
- Who can inspect: Registered design professional or another person acceptable to the fire code official.
- Scope and exceptions: Separate from the Housing Code six-year inspection. If the original design calculations are unavailable, a registered design professional must determine structural adequacy under § 1104.16.5. The fire code official’s accepted-person alternative applies to the recurring examination.
- Municipal codeHousing Code § 604(a)
- Municipal code
- Municipal codeFire Code §§ 1104.16.5 and 1104.16.5.1
- Municipal codeHousing Code § 908(b)–(c)
Residential balcony and exterior element research
These findings concern residential balconies, decks, exterior stairs, walkways and related fire escapes. Check the property scope and trigger: some duties apply during construction, after a notice, or when an inspection report is filed.
Inspection and reporting provisions
Separate fire-code examination of fire escapes
The Fire Code requires examination of exterior fire-escape stairs and balconies. Keep the report on site for the fire official.
Unverified — private hire
- Residential scope only: Fire-escape stairs and balconies covered by the Fire Code.
- Every five years or more often as requested by the fire code official.
- Registered design professional or another person acceptable to the fire code official.
- Fire Code § 113.2 generally makes the owner responsible. § 1104.16.5.1 allows an examiner accepted by the fire official. Private hire is unverified for the separate five-year rule. Housing Code § 604(a) is already listed separately.
- Fire Code §§ 1104.16.5 and 1104.16.5.1
- Supporting source
- Supporting source
- 2025 San Francisco Fire Code §§ 1104.16.5 and 1104.16.5.1
- Supporting source
Supporting research details
Structural examination of fire escapes · Verified mixed credentials
- Check structural adequacy and safety, including the ability to carry dead load plus the live load specified in the original design. Maintain the report on site for immediate production on request.
- Residential scope only: Covered fire escape stairs and balconies.
- Every five years or more frequently when requested by the fire code official.
- Registered design professional or other person acceptable to fire code official for the examination. Registered design professional must determine structural adequacy if original structural design calculations are unavailable.
- Use the local design-load rule. The separate §604 affidavit does not displace the Fire Code schedule.
- Current 2025-edition SF Fire Code online text §§1104.16.5 and 1104.16.5.1.
Fire escape structural examination · Provider and scope as documented
- Residential scope only: Fire escape stairways and balconies
- Every 5 years; more often if ordered
- Registered design professional or another person accepted by the fire code official.
- Check structural adequacy and safety. Keep the report at the property; make it available on request.
Fire-escape structural examination · Source checked · publication pending
- A registered design professional, or another person accepted by the fire code official, must examine fire-escape stairs and balconies for structural safety at least every five years. The official may require a shorter interval. Keep the report on site and make it available when requested.
- Residential scope only: Fire-escape stairways and balconies
- Every five years; sooner if required
Structural examination of fire escape stairs and balconies · Authority scope and qualifications vary
- Keep the report on site. Separate legal basis from Housing Code § 604, with potential overlap for a given building.
- Residential scope only: Fire escape stairways and balconies subject to the local fire code
- Every 5 years or sooner when the fire code official requests it
- Registered design professional or someone acceptable to the fire code official. A registered design professional must determine adequacy when the original calculations are unavailable.
- 80–81
Weather-exposed structural elements and exits
Arrange a qualified inspection of covered wood and metal exterior structures and file the signed affidavit with Housing Inspection Services.
Existing verified card
- Residential scope only: Weather-exposed decks, balconies, landings, exit corridors, stairs, guards, handrails and fire escapes at apartment buildings.
- Every six years. A property subject to HSC § 17973 can align the local affidavit date once, with a maximum of seven years between affidavits.
- Qualified contractor, certified inspector or building official, licensed architect, or licensed civil or structural engineer. The city bars its own employees from performing the inspection.
- San Francisco Housing Code §§401 and 604(a); Ordinance 92-26, effective June 15, 2026
- Signed Ordinance 92-26, pp. 2–3
- Supporting source
Supporting research details
Weather-exposed structural elements and exits · Verified mixed credentials
- Have a qualifying professional check all covered weather-exposed elements for safe working condition, rot, fungus, deterioration, decay and improper alterations. File the signed DBI affidavit.
- Residential scope only: covered weather-exposed wood and metal decks, balconies, landings, exit corridors, stairs, guards, handrails and fire escapes at apartment buildings, including covered residential condominiums with three or more dwellings. Confirm the definitions in Housing Code §401.
- Every six years. For properties subject to California Health and Safety Code (HSC) §17973, one advance or deferral may align deadlines, with no more than seven years between local filings.
- CSLB A, B or C-5 contractor with five years holding the qualifying classification and five years constructing multistory wood-frame buildings, recognized certified building inspector/official, or licensed architect/civil/structural engineer.
- Older DBI notice lists five years and a pest-control route removed by 92-26. Alignment is limited to §17973. State duties and SF Fire Code §1104.16.5.1 must be evaluated independently.
- Current online code; signed Ordinance 92-26 PDF pp. 2–3
Exterior structural maintenance and inspection affidavit · Provider and scope as documented
- Residential scope only: Covered exterior wood and metal elements at apartment buildings
- Every 6 years; one-time alignment with state deadline may extend interval to no more than 7 years
- Qualifying A/B/C-5 contractor, recognized certified inspector/official, or licensed architect/civil/structural engineer; inspector must not be employed by the City and County while inspecting.
- File signed city affidavit. Includes specified decks, balconies, stairs, guards and fire escapes; separate from the five-year Fire Code examination.
Exterior structural maintenance inspections · Source checked · publication pending
- Have a qualified inspector check the covered exterior decks, balconies, landings, exit corridors, stairs, guards, handrails and fire escapes for safe condition and operation. File the signed affidavit with Housing Inspection Services every six years. A property subject to California Health and Safety Code § 17973 may align the deadlines once, with no more than seven years between affidavits.
- Residential scope only: Specified weather-exposed wood and metal elements of apartment buildings
- Every six years
Weather-exposed structural elements and exits · Historical source
- Owner files the signed affidavit with Housing Inspection Services. Residential condominium coverage is subject to §401. The former five-year guidance and former pest-control route are superseded by Ordinance 92-26. Check state and fire-code duties separately.
- Residential scope only: Weather-exposed decks, balconies, landings, corridors, stairways, rails and fire escapes at covered apartments
- Every six years; one-time alignment with HSC §17973 may allow up to seven years between affidavits.
- CSLB A, B or C-5 contractor with five years holding the qualifying classification and five years constructing multistory wood-frame buildings, recognized certified building inspector/official, or licensed architect/civil/structural engineer.
- Ordinance 92-26, pp. 2–3
Last researched date: July 28, 2026