California balcony inspection guide
Does SB 721 or SB 326 apply to your building?
Check the criteria for your building
SB 721: Apartments and rental buildings
All three conditions must be met.
1. The building is outside a common interest development
Check the deed and recorded ownership documents. SB 721 excludes common interest developments, including condominium projects. Renting out a condo does not change its legal ownership type.
2. The building has at least three multifamily dwelling units
Count the dwelling units in each building separately. A mixed-use building can qualify if it has enough homes. Shops and offices do not count as dwelling units.
3. At least one qualifying Exterior Elevated Element (E3)
Check balconies, decks, porches, stairways, walkways and entry structures, including their supports and railings. To qualify, the structure must:
- Extend beyond the exterior walls of the building.
- Have a walking surface more than six feet above ground level.
- Be designed for people to use or occupy.
- Rely wholly or substantially on wood or wood-based products for support or stability.
Check all the outdoor structures on the building. Finding one that falls outside the definition does not rule out another that qualifies. The inspection includes the qualifying structure’s associated waterproofing.
SB 326: Condominium projects
All three conditions must be met.
1. The building is legally part of a condominium project
Check the recorded condominium plan and property documents. An HOA name or the word “townhome” alone does not establish whether the development is a condominium project.
2. The building has at least three attached multifamily dwelling units
Count the dwelling units that are attached within the same building. Do not add detached homes or separate duplexes together just because they share an association.
3. At least one qualifying Exterior Elevated Element (E3) that is maintained or repaired by the association.
Check the supports that extend beyond the exterior walls and carry loads to the building from decks, balconies, stairways, walkways and their railings. The structure must:
- Have a walking surface more than six feet above ground level.
- Be designed for people to use or occupy.
- Rely wholly or substantially on wood or wood-based products for support.
The inspection includes the associated waterproofing.
Use the association’s governing documents to confirm responsibility for the supports and waterproofing. A resident’s duty to clean a balcony surface does not settle who must maintain or repair the structure. Check the whole building even if your own unit has no balcony.